Fabric for Protective Suit(Isolation gown safety clothes) Implementation standards     GB19082-2009/EN14126-2003
Art No. Composition Features Weight(GSM) Width(cm) USE Protection class Implementation standards Breathable and moisture permeable index(mm)
LM001-F SS+PE 65±5 160 Civil Class one GB19082-2009 2500-3000
LM002-F SS+PE Anti-static 65±5 160 1. Specimen transportation and inspection personnel;
2. Medical observers of close contacts;
3. Medical staff for pre-screening triage and fever diagnosis.
Class one GB19082-2009 2500-3000
LM008-F Poly fabric+TPU Anti-static 80±3 145 Civil Class one GB19082-2009 2700-3500
LM005-F SS+TPU+SS Anti-static、Flame retardant 90±5 150 1. Sampling personnel for close contact with symptoms, observation or confirmed cases;
2. Medical staff who perform brachytherapy on suspected or confirmed cases;
3. Staff who handle patients’ blood, secretions, feces, and dead patients.
4. It is commonly used in second-class qualification production enterprises such as biological agent experiments, virus detection, operating rooms, intensive care units (ICU), and rescue rooms.
Class two GB19082-2009
EN14126-2003
2700-3500
LM006-F SS+TPU Anti-static 58±5 160 1. Sampling personnel for close contact with symptoms, observation or confirmed cases;
2. Medical staff who perform brachytherapy on suspected or confirmed cases;
3. Staff who handle patients’ blood, secretions, feces, and dead patients.
4. It is commonly used in second-class qualification production enterprises such as biological agent experiments, virus detection, operating rooms, intensive care units (ICU), and rescue rooms.
Class two GB19082-2009
EN14126-2003
2700-3500
LM007-F SS+PTFE
(Nanifilm)
Anti-static、Flame retardant 55±3 155 1. Sampling personnel for close contact with symptoms, observation or confirmed cases;
2. Medical staff who perform brachytherapy on suspected or confirmed cases;
3. Staff who handle patients’ blood, secretions, feces, and dead patients.
4. It is commonly used in second-class qualification production enterprises such as biological agent experiments, virus detection, operating rooms, intensive care units (ICU), and rescue rooms.
Class two GB19082-2009
EN14126-2003
>8000
Use: medical staff use to isolate germs, harmful ultrafine dust, acidic solutions, saline solutions, blood, etc.
Antistatic: The requirement is to prevent the static electricity in the operating room, which will cause the adsorption of a large amount of dust and bacteria on the patient’s wounds, and prevent the spark generated by static electricity from detonating the volatile gases in the operating room and affecting the accuracy of the precision instruments. The power should be no more than 0.6μC / piece, and the static decay time should not exceed 0.5s.
Flame retardant: High-quality flame retardant properties effectively prevent the protection of medical personnel from the combustion of alcohol flames. Burning time ≤15s, smoldering time ≤10s, damage length ≤200mm

Pass all
Resistance to Water Penetration
Water-Vapour Transmission
Resistance to Surface Wetting
Tensile Strength
Elongation at Break
Flammability Test
Electrostatic Decay Performance
Anti Synthetic Blood Penetrate Performance
Filtering Efficiency